Siemens Drive Fault Code
Overview
The Sinamics Frequency Converter Fault Codes, like its other counterparts, is equipped with an information panel designed to make communication between the operator and the converter as easy and comfortable as possible. When commissioning equipment using this panel, the device is programmed and configured, and in case of an unforeseen situation, Siemens fault codes are displayed on the frequency converter panel, which caused an emergency stop of the equipment. You can find all possible sinamics errors in the user manual (manual) in PDF format, which can be downloaded from our website. Eliminating the cause of the error and resetting it on the converter will allow you to resume operation as soon as possible. Unfortunately, not all errors can be corrected by yourself, some sinamics errors can only be corrected in specialized service centers.
SIEMENS VFD
SIEMENS VFD FAULT CODES
F06010 – Error in the power supply.
F06300 – The mains voltage is too high.
F07410 – Error in actual current measurement.
F07412 – Motor shaft movement is not expected.
F07413 – Motor shaft motion is more than 45 degrees different than expected.
F07452 – Difference between setpoint and actual value of motor shaft position.
F07453 – Error processing actual position value.
F07490 – The drive is in the “on inhibiting” state.
F07901 – The maximum allowable motor speed has been exceeded.
F07902 – The error code means that the engine has stopped.
F30003 – DC link voltage too low.
F30004 – The temperature of the power supply heat sink has exceeded the allowable value.
F30021 – A ground fault has occurred.
A30031 – Hardware current limit. The phase “U”. The hardware current limit for this phase has been reached.
F30035 – Overheating. The air temperature at the inlet to the power supply has exceeded the allowable limit.
F30040 – 24 V power supply failure. The 16 Volt threshold has fallen below more than 3 ms.
F30045 – Low supply voltage.
F30885 – No communication with one of the system’s Drive-Cliq Power Modules, although it is configured.
F31115 – Signal amplitude error A or B.
F31120 – Encoder supply voltage failure.
F31116 – A + B signal monitoring amplitude error.
SINAMICS VFD MICROMASTER FAULT CODES
F0001 – Overcurrent.
F0002 – Overvoltage.
F0003 – Undervoltage.
F0004 – Converter overheating.
F0005 – Excess I2t.
F0011 – Engine overheating by I2t.
F0041 – Error when measuring stator resistance.
F0051 – Parameter error in EEPROM.
F0052 – Stack error
F0060 – No response from the dedicated ASIC board.
F0070 – Error setting via a communication board.
F0071 – No data on the subsequent protocol (RS232) during the timeout.
F0072 – No data on the subsequent protocol (RS485) during the timeout.
F0080 – No input signal at the analog input.
F0085 – External failure.
F0101 – Stack overflow.
F0221 – PI controller feedback below the minimum value.
F0222 – PI controller feedback above the maximum value.
F0450 – Error during BIST – testing.